Last updated
Canthal Tilt
Runs in your browser. Your photo is not uploaded.
A canthal tilt of +3° is "positive" on some calculators and "neutral" on others, because each site draws its own cutoffs. This tool measures the angle of each eye from one front photo, shows the raw degrees first and the label second, and draws the four corner points it used so you can check them. The photo stays in your browser. It is free and asks for no account.
What this canthal tilt tool measures
Canthal tilt is the direction of the line from an inner eye corner to its outer corner. The tool uses points 133 and 33 on the right eye and 362 and 263 on the left, meaning the photographed person's eyes, so a mirrored selfie preview looks swapped. In this canthal tilt tool the angle is the arctangent of the height difference over the horizontal gap, and an outer corner higher than the inner one gives a positive number.
Before measuring, the tool levels the face on the midline between points 10 and 152, forehead top to chin. It does not level the eyes or pupils, because that would cancel a real difference between the two sides. You get the left angle, the right angle, their average and a label.
Why other calculators give another label
The canthal tilt label comes from cutoffs. Here, an average of +4° or more is upturned and −1° or less is downturned; these are readability cutoffs, not scientific standards. The other bands below are as each page writes them.
| Average reading (hypothetical, degrees) | This canthal tilt tool | faceshapedetector.app | symmiapp.com | trymaxxing.com |
|---|---|---|---|---|
| +3.0 | Neutral (below +4) | Positive (above +2) | Positive (+2 or more) | Positive (+1 to +8) |
| −0.5 | Neutral (above −1) | Neutral (−2 to +2) | Neutral (between −2 and +2) | Neutral (−1 to +1) |
| −1.5 | Downturned (−1 or less) | Neutral (−2 to +2) | Neutral (above −2) | Not covered: its bands skip from −1 to −2 |
The same angle gets a different label depending on the site's convention, not on the face. That is why this canthal tilt tool puts the degrees first.
A worked example of canthal tilt on one eye
All numbers are hypothetical. After the face is upright, the inner corner is at (100, 250) and the outer corner at (190, 238), with y pointing down.
The gap is 190 − 100 = 90 px, and the outer corner sits 250 − 238 = 12 px higher. The angle is arctan(12 ÷ 90) = 7.6°. On its own, that single eye would sit above the +4° cutoff. If the other eye reads −2.0°, the average is (7.6 − 2.0) ÷ 2 = 2.8°, which is neutral. One eye slants up and one slants down, and the average hides both.
How one pixel moves the angle
Let the outer corner land one pixel lower, at 11 px above the inner corner. The angle is arctan(11 ÷ 90) = 7.0°, a change of about 0.6°. Now shrink the same eye to 45 px wide and 6 px high: it still reads 7.6°, but a one-pixel drop to 5 px gives arctan(5 ÷ 45) = 6.3°, a change of about 1.3°. The corner points behind a canthal tilt carry noise of a pixel or two, so on a small image the error can reach about ±1°, and a degree is not worth arguing over.
What published research says
| Source | Sample and method | What it reports | Use as a normal range? |
|---|---|---|---|
| Bashour and Geist, 2007 | Judges chose between original female faces and copies edited in Photoshop to exaggerate the inner-corner tilt | The exaggerated faces were chosen 93% of the time (p < 0.0001) | No: edited images, female faces, a forced choice |
| Lee et al., 2020 | 76 Korean patients, mean age 23.12, in a study of vertical orbital dystopia (eyes at different heights) | Mean tilt 8.45° ± 3.53° right and 8.42° ± 3.81° left; pupil-level difference 1.57 ± 1.10 mm | No: patients, not the general population |
| Online ranges such as "ideal 3 to 5°" or "normal −5 to +8°" | Written on commercial pages | Differ from page to page | No: no source I could confirm |
No reliable source found gives one normal canthal tilt range or an ideal angle. The authors of the first study suggest the effect may relate to palpebral fissure inclination, the slant of the eyelid opening.
Limits of a single front photo
The tool corrects head roll only. Nodding or turning the head still changes the projected corners in any canthal tilt reading, so face the lens squarely at eye level. Lashes, liner, shadow and glasses frames can hide an outer corner; the drawn lines let you see whether a point landed on the real corner. The points trace the open eye's outline, so a lid fold is invisible to this canthal tilt reading; what are hooded eyes explains lids. Where to stand and where to rest the phone are shown in the photo guide. Anything new in one eye, such as a drooping lid or discomfort, is for an eye doctor, not a degree reading.
This page reads the number only. For a downward reading, causes, age and styling sit on the negative canthal tilt page, and for an upward one on positive canthal tilt. The what are hunter eyes tool weighs this angle together with brow distance and eye spacing, and the eye type page reuses the angle with eye opening and spacing.
Canthal FAQ
Is a neutral angle bad?
No. Neutral is a label from the cutoffs above, and the canthal tilt reading itself is only a direction in degrees.
Why does another calculator give me a different label?
Each canthal tilt site sets its own bands, as the table shows. Compare the degrees, not the words.
Do the left and right eyes need to match?
No. Corners seldom sit identically, so the tool reports each eye on its own. The patient sample above is no guide to how far apart healthy eyes may be in canthal tilt.
How accurate is a phone photo?
A one-pixel shift moves the angle by roughly 0.6° to 1.3° in the example, so repeat the canthal tilt reading on two photos.
Does age change the reading?
This page reads one photo. Age is covered on the negative canthal tilt page.
Can the angle be changed?
This site gives no surgical advice on canthal tilt. Styling changes how the area looks, not the measured corners.
Is my photo uploaded?
Not for this measurement. The canthal tilt points and lines are computed in your browser.